zurn grease interceptor sizing

zurn grease interceptor sizing


Grease Trap Sizing Chart - Drain-Net

Learn the basic formula for sizing a grease trap or grease intercepotr.

Learn More

FOG FAQ - Union Sanitary District

Grease intensive Food Service Establishments such as a Mexican, Indian, Chinese, or Buffets, will require an outside grease interceptor installed with the 

Learn More

Specification Drainage Engineering Guide Grease, Hair

Z1173-RD – Sizes 200-800. GREASE INTERCEPTORS. ZURN PLUM PRODUCTS GROUPSPECIFICATION DRAINAGE OPERATION, 1801 PITTSBURGH AVENUE, ERIE, PA

Learn More

Specification Drainage Engineering Guide Grease, Hair, Solids ... - Zurn

GREASE INTERCEPTORS ZURN PLUM PRODUCTS GROUPSPECIFICATION DRAINAGE OPERATION, 1801 PITTSBURGH AVENUE, ERIE, PA 16502 PHONE 814/455-0921 FAX: 814/454-7929 WEBSITE: www.zurn.com Page 4 Four factors are critical to the proper operation of a grease interceptor: Design, Sizing, Proper Installation, and Maintenance.

Learn More

Zurn | Grease, Oil and Sediment Separation | Oil and Solids Interceptor

Zurn offers a full line of Oil and Solids Interceptors designed specifically for the auto industry with sizes up to 10,000 gallons. Traps & Primers. Stainless Drains. Light Commercial. Trench Drain Systems. Acid Neutralization. Liquid Volume Sizing (U.S. G/L) 50 (189)

Learn More

Grease Interceptor: 4 in Pipe Dia., 100 gpm Flow Rate, 180 lb

Grease Interceptor: 4 in Pipe Dia., 100 gpm Flow Rate, 180 lb Capacity, Polyethylene ; Overall Height 54 in ; Overall Width 31 in ; Overall Depth 66 in ; Max. Temp.

Learn More

Grease Interceptors Z1160 thru Z1174

Sizing - PDI Method Using Sink Volumes. Installation of Grease Interceptors. Maintenance of Grease Inteceptors. Product Information. Z1174 Installation Instructions. Z1192 Grease Recovery Appliance. Operations and Variations. Chemical Resistance Information. Materials and Finishes.

Learn More

GREASE INTERCEPTORS - Zurn

cannot be specified when the aluminum cover is used. –BB Timer Battery Backup(For Z1174) –C30 Cable Length of 30 Feet For Digital Display(For Z1192) –C45 Cable Length of 45 Feet

Learn More

Grease Traps - Drainage - The Home Depot

Zurn33 in. x 23 in. Steel Grease Trap with 3 in. No Hub Inlet · 33 in. x 23 

Learn More

Grease Interceptor Technical Information - Zurn

Grease Interceptor Technical Information · General Information · Application/Purpose · Operation of Grease Interceptors · Sizing - PDI Method Using Sink Dimensions.

Learn More

Grease Interceptor Sizing and Installation Guidelines

Table 4 on the next page (“HGI Sizing Chart”) is used to determine the size of HGI needed, if that is the type of grease interceptor being installed. In Example 1, based on 29 DFUs a 75 gallon per minute (gpm) unit would be required. In Example 2, a 50 gpm unit would be required.

Learn More

Grease Interceptor - GT2700 - Zurn

Zurn's Grease Interceptor GT2700 is recommended for removing and retaining grease from wastewater in kitchen and restaurant areas where food is prepared.

Learn More

UK Grease Trap Sizing Calculator BS EN 1825 - Aqua Mundus

Under the BS EN 1825 calculation, we can determine the correct size by two methods: OPTION 1 - Type of Kitchen This looks at the type of operation, such as restaurant, school, hospital etc and requires the input of average meals per day with the kitchen operational hours per day. OPTION 2 - Type of Equipment

Learn More

Grease Traps vs. Grease Interceptors

A grease trap is a small FOG removal unit designed for use in kitchen applications where the flow of water and amount of oil and grease produced 

Learn More

Sewer use grease interceptor policy - City of Sebastopol

The purpose of this document is to set forth the requirements for the sizing and installation of grease removal devices in.

Learn More

Grease Trap Sizing Guide - WebstaurantStore

Calculating Grease Trap Requirements For Dish Machines · 10-15 Gallon Capacity Dish Machine Tank: 15 Pound Grease Trap · 20-30 Gallon Capacity Dish Machine Tank: 

Learn More

GREASE INTERCEPTOR W/ USER NOTIFICATION SYSTEM

Note: Zurn grease interceptors with grease recognizing sensors are the use of a larger size interceptor than normal sizing indicates.

Learn More

GREASE INTERCEPTORS

GREASE INTERCEPTORS ZURN PLUM PRODUCTS GROUPSPECIFICATION DRAINAGE OPERATION, 1801 PITTSBURGH AVENUE, ERIE, PA 16502 PHONE 814/455-0921 FAX: 814/454-7929 WEBSITE: www.zurn.com Page 12 Z1171-TD and Z1173-TD Grease Interceptor With Top Draw-off To assist in the maintenance and cleaning process of grease inter-

Learn More

Building Drainage products | Grease, Oil and Solid Interceptors ... - Zurn

Grease Interceptors from Zurn's are CSA and PDI Certified. Our Grease, Oil and Solid Interceptors are high performing and come in different variants, the right fit for All of Your Separation Needs Liquid Volume Sizing (U.S. G/L) 50 (189) Grease Interceptor are manufactured with patented distributed flow pattern and corrosion resistant

Learn More

How to size your Grease Trap - Drain-Net Technologies

Sizing a Grease Trap by Flow Rate: Explanatory Note: This method uses total combined fixture capacity to define an actual (maximum) drainage load, which is in 

Learn More

PDF Grease Interceptor Sizing and Installation Guidelines - Tacoma PermitsPDF

Hydromechanical Grease Interceptor (HGI) Sizing Chart DFUs (1) HGI Flow (gpm) 8 25 13 35 20 50 35 75 172 100 216 150 342 200 428 250 576 350 720 500 (1) The maximum allowable number of DFUs that can be connected to the grease interceptor. The information in the above tables is from section 702.0 and tables 7-5, 10-2 and 10-3 of the

Learn More

Inquiry